.................................................................................................................................................................................................................. Centrifugal Pump Total Dynamic Head on Suction Lift
mac website creator

Calculating Total Dynamic Head (TDH) on Suction Lift Applications

Total Dynamic Head Suction Lift

Suction Lift Application

100 GPM of Water at 170 F

Find the Total Dynamic Head (TDH)


TDH = Total Discharge Head + Total Suction Lift


Suction:


Total Suction Lift= Static + Friction


Suction Static Lift---------------------------------------- 15'


Friction Suction Side-See Friction Resistance Chart Here-->


Total Length of 3" Pipe----------------------35'


See Friction Resistance Fitting Chart Here-->


(1) 90 deg 3" Elbow = 7.7' of Pipe----------7.7'


Total Equivalent Length of 3" Pipe---------42.7'


Friction = 4.96 x 42.7 / 100------------- 2.1'


Total Suction Lift = 15'(Static) + 2.1'(Friction) = 17.1'


 


Discharge


Total Discharge Head = Static + Friction


Discharge Static Head--------------------------------------22'


Friction Discharge Side-See Friction Resistance Chart Here-->


Total Length of 2" Pipe------------------------142'


See Friction Resistance Fitting Chart Here-->


(4) 90 deg 2" Elbow = 20.8(4x5.2)of Pipe---20.8'


Total Equivalent Length of 2" Pipe ----------162.8'


Friction = 35.8 x 162.8/100-----------------58.3'


Total Discharge Head = 22'(Static) + 58.3'(Friction) = 80.3'


Total Dynamic Head = Total Discharge Head + Total Suction Head= 80.3' + 17.1' = 97.4'