Fitting Chart
Fitting
Losses
Equivalent Length of Pipe in Feet
| Pipe
Diameter |
Valves |
| Gate |
Plug |
Globe |
Angle |
Check |
Foot |
| 1.5" |
0.9 |
- |
45 |
23 |
11 |
39 |
| 2" |
1.10 |
6.0 |
58 |
29 |
14 |
47 |
| 3" |
1.6 |
8.0 |
86 |
43 |
20 |
64 |
| 4" |
2.1 |
17 |
113 |
57 |
26 |
71 |
| 6" |
3.2 |
65 |
170 |
85 |
39 |
77 |
| Pipe
Diameter |
Elbows |
Tube
Turn |
Tee |
Enlrg |
Contr |
| 45 |
90 |
45 |
90 |
Strt |
Side |
1:2 |
3:4 |
2:1 |
4:3 |
| 1.5" |
1.9 |
4.1 |
1.4 |
2.3 |
2.7 |
8.1 |
2.6 |
1.0 |
1.5 |
1.0 |
| 2" |
2.4 |
5.2 |
1.9 |
3.0 |
3.5 |
10.4 |
3.2 |
1.2 |
1.8 |
1.2 |
| 3" |
3.6 |
7.7 |
2.9 |
4.5 |
5.2 |
15.5 |
4.7 |
1.7 |
2.8 |
1.7 |
| 4" |
4.7 |
10.2 |
3.8 |
6.0 |
6.8 |
20.3 |
6.2 |
2.3 |
3.6 |
2.3 |
| 6" |
7.1 |
15.3 |
5.8 |
9.0 |
10.2 |
31 |
9.5 |
3.4 |
5.6 |
3.4 |


|